2.4-2.7 Locking System
2.4-2.7 Locking System
The 2.4-2.7 locking System consists of anatomic and procedure specific plates for the treatment of various types of fractures of the distal radius. The system is comprised by 8 types of plates and by locking and cortical screws.
The system is available in a series of plates and screws manufactured by Pure Titanium (ISO 5832-2) and Titanium Alloy (ISO 5832-3), respectively, and another series manufactured by Stainless Steel (ISO 5832-1).
2.4-2.7 Locking System Options
2.4/2.7 Distal Radius Volar Side Column Locking Plates
- Available in 3 sizes (3-5 holes, 49-67 mm long)
- Right and left versions
- Indicated for fixation of extra- and intra-articular fractures of the distal radius, especially for highly comminuted fractures
2.4/2.7 LCP Distal Radius Volar Plates, Extra – Articular
- Available in 2 sizes (3 and 5 holes, 47 and 65 mm long)
- Right and left versions
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 Distal Radius Volar Side Locking Plates
- Available in 2 sizes (3 and 5 holes, 47 and 65 mm long)
- Right and left versions
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 LCP Distal Radius Volar Plates
- Available in 2 sizes (3 and 5 holes, 43 and 61 mm long)
- Right and left versions
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 LCP Distal Radius Plates
- Available in 2 sizes (5 and 6 holes, 48 and 57 mm long)
- Designed to match the anatomy of the radial column
- Reduced contact with the bone as to have minimum impact on the proper blood supply of the fractured region
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 LCP Distal Radius T-Plates
- Available in 2 sizes (3 and 4 holes, 40 and 49 mm long)
- Designed to match the anatomy of the radial column
- Reduced contact with the bone as to have minimum impact on the proper blood supply of the fractured region
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 LCP Distal Radius L-Plates
- Available in 2 sizes (3 and 4 holes, 40 and 49 mm long)
- Designed to match the anatomy of the radial column
- Reduced contact with the bone as to have minimum impact on the proper blood supply of the fractured region
- Indicated for fixation of extra-articular fractures of the distal radius
2.4/2.7 Multiaxial Distal Radius Volar Side Column Locking Plates
- Available in 3 sizes (3-5 holes, 4-66 mm long)
- Right and left versions
- The two columns at the head of the plate allow independent fine contouring of the radial and intermediate columns
2.7mm Locking Screws, Self - Tapping
- Available in 13 sizes (6-30 mm long, in 2 mm increments)
- Core diameter 2.0 mm
- Hexagonical head for use with 2.4 mm Screw Driver
- The self-taping feature eliminate the use of bone tap
2.4mm Cortical Screws, Self Tapping
- Available in 22 sizes (6-40 mm long)
- Core diameter 1.8 mm
- Hexagonical head for use with 2.4 mm Screw Driver
- The spherical design under the screw head provides compression whereas the thick core provides strength
- The self-taping feature eliminate the use of bone tap
2.4mm Locking Screws, Self - Tapping
- Available in 17 sizes (6-30 mm long)
- Core diameter 1.8 mm
- Hexagonical head for use with 2.4 mm Screw Driver
- The self-taping feature eliminate the use of bone tap